It appears that your cart is currently empty
Pressure Transducer - 0 to 5000 PSI
This pressure transducer is designed to connect to the NMEA 2000® network via a Maretron FPM100 Fluid Pressure Module.
Specifications:
Installation:
All Maretron pressure transducer assemblies are equipped with a 1/4 in. NPT male threaded fitting. Install the pressure transducer to a 1/4 in. NPT female fitting on the system or tank is to be monitored with a maximum torque of 150 in-lbs (16.95 Nm).
If you are monitoring a system where pressure spikes or transients will occur, or where the pressure will exceed the maximum pressure rating of the pressure transducer, install a Pressure Snubber (PT-SNUB-01) onto the system being monitored first, then install the pressure transducer to the female port on the pressure snubber.